Autokabina also produces a range of cheaper spray booths with a partner in China, which are cheaper than our European produced spray booths.

EC Line (cheapest spray booths)

EC 1

Heating: Infra-red (24kW)
Airflow Type: Vertical / Full down draft
Airflow: 20.000m3/h
Air Velocity: 0,2 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,5m
Ventilation: Intake generator (2 x 3kW)

EC 2

Heating: Diesel burner (116kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 20.000m3/h
Air Velocity: 0,2 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,5m
Ventilation: Intake generator (2 x 3kW)

EC 3

Heating: Diesel burner (116kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 20.000m
Air Velocity: 0,2 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,5m
Ventilation: Intake (2 x 3kW) and exhaust (1 x 4kW) generator

AD Line (Basic Spray Booths)

AD 1

Heating: Diesel burner (120kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,65m|
Ventilation: Intake generator (1 x 7,5kW)

AD 2

Heating: Diesel burner (210kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,65m
Ventilation: Intake generator (2 x 4kW)

AD 3

Heating: Diesel burner (210kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,65m
Ventilation: Intake (2 x 4kW) and exhaust (1 x 2,2kW) generator 

AD 4

Heating: Diesel burner (210kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,65m
Ventilation: Intake (2 x 4kW) and exhaust (1 x 5,5kW) generator 
lighting: Extra lighting (side walls)

IB Line (preferred spray booths for EU market)

IB 1

Heating: Diesel burner (210kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: 2 rows with grids
Inside dimensions: 6,9 x 4 x 2,65m|
Ventilation: Intake (1 x 7,5kW) and exhaust (1 x 7,5kW) generator 

IB 2

Heating: Diesel burner (210kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,65m|
Ventilation SIEMENS: Intake (1 x 7,5kW) and exhaust
(1 x 7,5kW) generator 
+ stronger booth construction, floor and lamps construction

IB 3

Heating: Diesel burner (294kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow: 25.000m
Air Velocity: 0,25 m/s
Floor type: Inside metal basement
Inside dimensions: 6,9 x 4 x 2,65m|
Ventilation SIEMENS: Intake (1 x 7,5kW) and exhaust
(1 x 7,5kW) generator 
+ stronger booth construction, floor and lamps construction

FT Line (spray booths for trucks)

FT Full Down

Heating: Diesel burner (2 x 300kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow intake: 84.000m
Airflow exhaust: 76.000m
Air Velocity: 0,31 m/s
Floor type: 2 rows with grid
Inside dimensions: 15 x 5 x 5m|
Ventilation: Intake (4 x 7,5kW) and exhaust (2 x 15kW) generator 

FT Semi Draft

Heating: Diesel burner (395kW) or Gas burner
Airflow Type: Semi-Vertical / diagonal draft
Airflow intake: 48.000 m3/h
Airflow exhaust: 45.000 m3/h
Air Velocity: 0,54 m/s
Floor type: exhaust wall in the back wall
Inside dimensions: 15 x 5 x 5m|
Ventilation: Intake (2 x 9kW) and exhaust (1 x 18,5kW) generator 

FT Side Draft

Heating: Diesel burner (2 x 300kW) or Gas burner
Airflow Type: Vertical / Full down draft
Airflow intake: 84.000m
Airflow exhaust: 76.000m
Air Velocity: 0,31 m/s
Floor type: exhaust walls in the side walls
Inside dimensions: 15 x 5 x 5m
Ventilation: Intake (4 x 7,5kW) and exhaust (2 x 15kW) generator 

PB Line (Preparation station)

PB1

Heating: Without heating
Airflow Type: Horizontal draft
Airflow: 15.000m
Exhaust type: Rear exhaust wall

PB2

Heating: Without heating
Airflow Type: Vertical / Full down draft
Airflow: 15.000m
Exhaust type: 2 exhaust channels with grids

PB4

Heating: Without heating
Airflow Type: Vertical / Full down draft
Airflow: 15.000m
Exhaust type: 2 exhaust channels with grids
Inside dimensions: 6 x 3,9 x 2,7m


PB5

Heating: Without heating
Airflow Type: Semi-Vertical draft
Airflow: 15.000m
Exhaust type: Rear exhaust wall
Inside Dimensions: 6 x 3,9 x 2,7m


PB5 plus

Heating: Diesel burner
Airflow Type: Semi-Vertical draft
Airflow: 15.000m
Exhaust type: Rear exhaust wall
Inside Dimensions: 6 x 3,9 x 2,7m

PB6

Heating: Without heating
Airflow Type: Vertical / Full down draft
Airflow: 15.000m
Exhaust type: Inside metal basement
Inside Dimensions: 6 x 3,9 x 2,7m

PB6 plus

Heating: Diesel burner
Airflow Type: Vertical / Full down draft
Airflow: 15.000m
Exhaust type: Inside metal basement
Inside Dimensions: 6 x 3,9 x 2,7m

PMR Line (Mixing room)

PMR1

Airflow: 2.300m
Room air exchange: 73x /h
Inner dimensions: 3,45 x 2,3 x 2,65m


PMR2

Airflow: 2.300m
Room air exchange: 83x /h
Inner dimensions: 
4,6 x 2,3 x 2,65m


PMR3

Airflow: 3.500m
Room air exchange: 100x /h
Inner dimensions: 
5,75 x 2,35 x 2,65m